S7-300 CPU 314

經(jīng)常死機(jī),不運(yùn)行任何程序,只能手動(dòng)啟動(dòng)。讀取CPU故障緩存區(qū)信息如下,請(qǐng)問(wèn)高手如何處理:

Event 10 of 10: Event ID 16# 1381 Request for manual warm restart STOP due t STOP caused b">

国产精品久久人妻互换毛片,国产av国片偷人妻麻豆,国产精品第12页,国产高清自产拍av在线,潮喷大喷水系列无码久久精品

技術(shù)頻道

S7-300CPU死機(jī)故障

S7-300 CPU 314

經(jīng)常死機(jī),不運(yùn)行任何程序,只能手動(dòng)啟動(dòng)。讀取CPU故障緩存區(qū)信息如下,請(qǐng)問(wèn)高手如何處理:

Event 10 of 10: Event ID 16# 1381 Request for manual warm restart STOP due t STOP caused by stop switch being activated Startup information: - Startup without modified system configuration - No difference between setpoint and actual configuration - Time for time stamp at the last backed up power on - Single processor operation Current/last startup type: - Warm restart triggered by switch setting; last power on backed up Permissibility of certain startup types: - Manual warm restart permitted - Automatic warm restart permitted Last valid operation or setting of automatic startup type at power on: - Warm restart triggered by switch setting; last power on backed up OB number: 100 OB not found, or disabled, or cannot be started in the current operating mode Incoming event 02:08:36:885 pm 03/28/96

正如你所說(shuō),MW250的值指的是I/O錯(cuò)誤。
根據(jù)你的具體情況,我個(gè)人認(rèn)為問(wèn)題出在程序中——因?yàn)槿绻墙M態(tài)出現(xiàn)錯(cuò)誤,運(yùn)行一開始就會(huì)報(bào)錯(cuò)。
這里介紹在線診斷的方法,找出問(wèn)題程序:
1、當(dāng)出現(xiàn)停機(jī)事件時(shí),在STEP7中進(jìn)入聯(lián)機(jī)方式,按“CTRL+D”,出現(xiàn)如下畫面:


2、切換到“Diagnostic Buffer”標(biāo)簽頁(yè)


3、尋找出現(xiàn)你所描述故障的診斷項(xiàng),點(diǎn)擊它,將指示出錯(cuò)的程序塊


4、點(diǎn)擊“OPEN BLOCK”,編輯器將會(huì)打開故障塊,并以顏色指示故障代碼。以次方法,排除全部故障代碼。
預(yù)祝你成功!
==========